All posts by SpectraAdmin

EPR電子順磁共振儀耗材 Miscellaneous EPR Supplies

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz) 
EPR Sample Tubes and Accessories
EPR Cells
Dewar Inserts
Dewar Flasks (Cold-Finger Dewars)
Variable Temperature Accessories
Electrolytic Cells for EPR
‧ Miscellaneous EPR Supplies

Miscellaneous EPR Supplies
•Sample Handling Accessories
•EPR/NMR Tube Caps
•NMR/EPR Tube Racks
•NMR/ EPR Tube Labels
•NMR/EPR Tube Tip-off Manifold
•pH Electrode and Connectors

Sample Handling Accessories

Stainless Steel EPR Spatula

Handling powder samples is easy with the right tool; getting a tiny sample into a 5mm EPR tube should never be a struggle again. Unlike ordinary spatulas, our SST version fits into the most common EPR tubes. Add or remove samples easily; scoop samples with the round end, or pry stiff samples with the sharp-edged flat end. Freeze-dry your samples right in the tube because now they’re so easy to remove.

Many of our customers love this valuable tool. Order yours today!

Pipets – Manufactured By Wilmad-LabGlass

Use our NMR pipets for your EPR work as well for easy addition or removal of liquid samples from your EPR sample tube.

• Economical – compared to replacing EPR tubes broken using the wrong tools.

• Designed to reach the bottom of the longest EPR sample tube.

• Packaged conveniently in packs of 100.

• Two sizes are available to accommodate your tube length.

**Don’t forget to order your latex rubber pipet bulbs (804).

Note: Not recommended for heavy-walled NMR tubes.


Latex NMR
Pipet Bulb

 

 
Additional Pipets and Accessories

EPR Filters and Funnel
Our Sintered Glass EPR Sample Filters remove suspended particles 60 microns in diameter or larger.

Hamilton Gas-Tight Syringes
Gas-tight and inert, these specially selected Hamilton syringes are ideal for EPR sample handling. Use with stainless steel or Teflon needles.

Stainless Steel Needle
Needles are 2 inches long and have a beveled point. Ask customer service about longer needles.

NMR/EPR Tube Caps – Disposable


Disposable Tube Caps are manufactured from molded Ethylene Vinyl Acetate* or Polyethylene depending on the tube OD. The different colors help track samples based on various reference solvents.

Our popular 5mm size is available in eight colors.

New 5mm Polyethylene Cap for Automated Systems.

Packaged in bags of 100 or 1000 except where noted.


*Technical Tips:Please avoid using disposable NMR caps when CDCI3serves as the reference solution as the material(s) could be dissolved. When using CDCI3, we recommend PTFE caps (WG-1264-) which are only compatible with our Precision tubes.

**Replacement cap with hole for WGS-5BL.

***Cap for Automatic Sampling Systems; 5mm Tube.

Automated Handling Cap
NMR/EPR Tube Caps – PTFE

 

 

 

Pictured on tube

Our PTFE NMR/EPR Tube Caps are machined to exact specifications with smaller gyroradius and more homogeneous mass distribution than disposable caps providing better spinning stability. They are recommended for experiments at high – ultra high field and those using Chloroform as the reference solution. They will only fit our Precision tubes due to the tight tolerance.

NMR/EPR Tube Caps – Gas-Tight

Our Gas-Tight Tube Caps are ideal for experiments that require an air-tight environment under vacuum or low pressure less than 1 bar. Use with our Medium-Walled and Heavy-Walled NMR tubes for better seal and robustness in variable temperature experiments.

Serum Caps allow easy access via syringe needle.

NMR/EPR Tube Racks

Three styles available for our NMR and EPR Tubes
820-A
Lightweight polypropylene rack maximizes your benchtop storage capacity and is virtually inert.
WG-1301
Coated steel rack is completely encased in inert polyvinylchloride.

WG-2442
Stainless Steel Rack.

Pressure Sensitive NMR/EPR Tube Labels

These labels are a handy alternative to marking your NMR or EPR sample tubes. Each fits the circumference of the tube precisely with no overlapping to guarantee symmetry in spinning experiments.

NMR/EPR Tube Tip-off Manifold

How to make sealing your NMR/ EPR tubes easy!
If you struggle preparing NMR/EPR samples of air-sensitive mixtures, there is a simpler way! Use our NMR/EPR Tube Tip-off Manifold. You’ll find vacuum transfers, freeze-pump-thaws and sample sealing easy to complete. Fuse the manifold port quickly to your vacuum rack. The chemical resistance is excellent, only Viton®, Teflon®and Pyrex®come in contact with your sample. Tube connects to a threaded aluminum bushing isolated from the vacuum by a Teflon high-vacuum rotary valve. A twist of the wrist opens and closes both the rotary valve and port bushing.

pH Electrode and Connectors

Does your pH electrode fit into 5mm tubes? Most aren’t small enough to fit even a 10mm EPR tube. Not ours! The Combination pH Electrode for NMR/EPR Tubes fits easily into our thin wall 5mm EPR tube (e.g. 703-PQ).

It’s the only electrode your lab will ever need. It’s so versatile, it works for nearly all pH measurements.

pH Electrodes

Electrode Reference Solutions and Cleaners

EPR電子順磁共振儀耗材 Electrolytic Cells for EPR

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)     
EPR Sample Tubes and Accessories     
EPR Cells    
Dewar Inserts     
Dewar Flasks (Cold-Finger Dewars)     
Variable Temperature Accessories     
‧ Electrolytic Cells for EPR  
Miscellaneous EPR Supplies     

Electrolytic Cells for EPR
•Wilmad’s Electrolytic Cell Assemblies
•Components for Wilmad’s Electrolytic Cell Assembly
•Electrode Reference Solutions and Cleaners

Wilmad’s Electrolytic Cell Assemblies

Study electrolytically generated radicals in aqueous solutions.

Avoid alkali metal reductions, the associated sample sensitivity to air or moisture and background signals! Never deal with a high vacuum apparatus again!

The electrochemical or coulometric generation of radicals in aqueous media has been employed successfully for years. It’s ideal for biological samples because of the control afforded by voltaic methods. Just connect Wilmad’s Electrolytic Cell to a potentiostat.

Controlled oxidation-reduction reactions can be carried out right in the EPR cavity! A complete cell includes two Calomel Reference Electrodes, a pair of Platinum Electrodes, and a gas bubbler for deoxygenation. Wilmad provides the Electrolytic Cell Assembly as a complete unit with CFQ or Suprasil®Flat Cell, or you can order components separately. Electrolytic cells are available for the TE102or TE011cavities of all spectrometers.

Components:

Flat Electrolytic Cells have two10/30 outer joints, one for the Gas Bubbler and one Platinum Electrode at the top and a single5/20 outer joint at the bottom for the other Platinum Electrode. The flat section is either CFQ or Suprasil. The remainder of the Flat Cell is CFQ. You need a minimum of 15mL of sample solution to make contact with the electrodes and gas bubbler. The cell width for JEOL spectrometers is 10mm outside; product number WG-810-J-A (-Q). For all other spectrometers, the cell width is 10.5mm outside, product number WG-810-A (-Q).

The Gas Bubbler Assembly is a three-piece Pyrex chamber which holds part of your sample. It has three10/30 outer joints at the top for the Gas Bubbler and two Calomel Electrodes. The lower10/30 inner joint fits into the top of the Flat Electrolytic Cell. Nitrogen should be bubbled through the solution before and during your experiment to remove paramagnetic oxygen and mix the sample during electrolysis; product numbers WG-810-B-1, WG-810-B-2, WG-810-G.

Platinum Electrodes are prepared using 0.016″ (0.4mm) diameter wire. The upper electrode, WG-810-C, uses 8″ (203mm) of platinum and acts as the working electrode in oxidation reactions. The lower electrode, WG-810-D, has only 2″ (50mm) of platinum and acts as the auxiliary electrode in oxidation reactions. If you add a few drops of mercury to the cell, the lower electrode can be used as the working cathode in reduction reactions. Each Platinum Electrode incorporates a Pt-to-W weld. The tungsten (W) external wire lets you quickly clip your potentiostat leads to the electrode.

Electrolysis Limits in Water (vs. Saturated Calomel Electrode)

Calomel Electrodes are included in two lengths, one 13″ (330mm) and the other 83/4” (222mm). Connect your potentiostat to the half cell at a tungsten wire that penetrates the electrode wall. Add mercury in the outer chamber to a height that makes contact with the tungsten lead. Each electrode provided with a stopper. Not supplied with mercury. Electrolytes sold separately.

Wilmad Electrolytic Cell Assemblies

TIP: An electrolytic cell designed by Prof. Robert Allendorfer of SUNY, Buffalo and sold by Bruker Instruments offers improved sensitivity using a cylindrical TM110cavity. Its use is recommended when sample sensitivity is low.

Remember: Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

Components for Wilmad’s Electrolytic Cell Assembly

Please note: Items marked “CALL” are custom manufactured – please contact Customer Service for single piece or lot pricing.

Flat Electrolytic Cells
These cells have two10/30 outer joints, one for the Gas Bubbler and one Platinum Electrode at the top and a single5/20 outer joint at the bottom for the other electrode. The flat section is either CFQ or Suprasil. The remainder of the Flat Cell is CFQ. A minimum of 15mL of sample solution to make contact with the electrodes and gas bubbler. The cell width for JEOL spectrometers is 10mm outside. For all other spectrometers, the cell width is 10.5mm outside.

Gas Bubbler Assembly
A three-piece Pyrex chamber which holds part of your sample. It has three10/30 outer joints at the top for the Gas Bubbler and two Calomel Electrodes. The lower10/30 inner joint fits into the top of the Flat Electrolytic Cell. Nitrogen should be bubbled through the solution before and during your experiment to remove paramagnetic oxygen and mix the sample during electrolysis.

Platinum Electrodes
Prepared using 0.016″ (0.4mm) diameter wire. The upper electrode, WG-810-C, uses 8″ (203mm) of platinum and acts as the working electrode in oxidation reactions while the lower electrode, WG-810-D, has only 2″ (50mm) of platinum and acts as the auxiliary electrode. Adding a few drops of mercury to the cell allows the lower electrode to function as the working cathode in reduction reactions. Each Platinum Electrode incorporates a Pt-to-W weld. The tungsten (W) external wire lets you quickly clip your potentiostat leads to the electrode.

Calomel Electrodes
Supplied in two lengths, one 13″ (330mm) and the other 83/4” (222mm). Connect your potentiostat to the half cell at a tungsten wire that penetrates the electrode wall. Add mercury in the outer chamber to a height that makes contact with the tungsten lead. Each electrode is provided with a stopper.

Remember: Like many Quartz products for EPR, Electrolytic Cell components can often be repaired for costs that are less than new components. Contact Customer Service to ask about this service.

Electrode Reference Solutions and Cleaners

Calomel Reference Electrodes utilize a 3M potassium Chloride (KCl) solution saturated with Silver Chloride (AgCl). Use it to fill or replace reference solution in any pH or other electrode which incorporates a Calomel Reference.

In addition, we provide cleaning solutions which can be used to remove specific surface contaminants from your reference electrode junction.

EPR電子順磁共振儀耗材 Variable Temperature Accessories

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)     
EPR Sample Tubes and Accessories    
EPR Cells    
Dewar Inserts   
Dewar Flasks (Cold-Finger Dewars)     
‧ Variable Temperature Accessories  
Electrolytic Cells for EPR     
Miscellaneous EPR Supplies     

Variable Temperature Accessories
Replacement Parts for VT Systems

Need a replacement component for your variable temperature system?
Since Wilmad offers VT replacement components at prices significantly lower than the Original Equipment Manufacturer (OEM), why pay more? Wilmad components are equivalent or, in some cases, better in quality than you get from your EPR Spectrometer manufacturer.

You’ll get the best performance possible with Wilmad transfer dewars. Most are silvered for maximum thermal insulation. Where it has been possible, Wilmad transfer dewars are fully vacuum-jacketed, right to the end of socket and ball joints, so you get the most stable temperatures.
Bruker VT Transfer Dewar
The Bruker ER 4121 VT Variable Temperature System includes a long transfer dewar and a heater that goes inside it. The diameter and length of the heater and the transfer dewar has varied over the years, so choosing the right size dewar for your system was a real challenge.
Wilmad has made replacing the transfer dewar simple, though. Working closely with Bruker, we’ve developed two designs which work with all Bruker VT systems. The long version, WG-842-MX, works with all Bruker EPR spectrometers with magnets > 18 cm diameter. The shorter one works with all smaller magnets.

Wilmad’s versions of these transfer dewars are better than Bruker’s. We add a hollow ball joint for better thermal stability.

Only Wilmad makes a replacement for Varian’s E-257 Immersion Transfer Dewar!

Fully compatible with Varian’s E-257 VT System, this Immersion Transfer Dewar, Wilmad’s product number WG-760, incorporates a Kovar flange that fits the heat exchanger. It works better than the original transfer dewar of your VT System because it connects to the elbow transfer dewar through a jacketed socket.

This Elbow Transfer Dewar is better than the original you got from Varian!

You’ll get better performance with Wilmad’s WG-840 series of Elbow Transfer Dewars. That’s because we’ve redesigned the dewar to include a jacketed ball joint, so your cold carrier gas stays cold! No frosting!

It’s made with hooks that let you firmly hold the ball in the socket of the immersion transfer dewar (Wilmad’s product number WG-760) with springs.

You won’t need to rearrange your laboratory, either. Wilmad’s Elbow Transfer Dewars are available in three lengths, so you can choose the one that’s best for your setup. Call us for custom lengths.

Our special transfer dewar makes your VT setup more versatile!

Is the height of your replacement or new Nitrogen Evaporator Dewar too high or short for your VT setup? No problem. Wilmad has a solution. Our Bridge Transfer Dewar, WG-843, makes adjusting the flow path of your VT carrier gas easy!

Ideal for Bruker VT systems. Just turn the Evaporator Dewar Head around, place the Bridge Transfer Dewar between your long transfer and the Evaporator Dewar, and you cover the new angle.

This special transfer dewar can save you money and headaches. No custom manufacturing charges for a specially designed replacement part.

NOTE: While most EPR glassware is made from quartz, a few variable temperature components are actually made from Pyrex. Please note the material when ordering.

 

EPR電子順磁共振儀耗材 Dewar Flasks (Cold-Finger Dewars)

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)      
EPR Sample Tubes and Accessories    
EPR Cells    
Dewar Inserts    
‧ Dewar Flasks (Cold-Finger Dewars)  
Variable Temperature Accessories      
Electrolytic Cells for EPR     
Miscellaneous EPR Supplies    

Dewar Flasks (Cold-Finger Dewars)
•Large Nitrogen Dewar Flasks
•Liquid Nitrogen Dewar Flask

Large Nitrogen Dewar Flasks

Want the easiest way to take your samples to liquid nitrogen temperatures?
Dewar Flasks provide you with a convenient alternative to VT systems for studies at -195°C. Wilmad makes flasks for almost all common cavity resonators including those requiring reservoirs “off-set” from the center axis. Use these for cavities with iris controls near the Dewar Flask reservoir. Select either Clear Fused Quartz (CFQ) or Suprasil “cold-fingers.” All Dewar Flasks are silvered about the reservoir. Each Dewar Flask is shipped with protective nylon meshing.

Large 150mL Dewar Flasks
For longer experiments (25-45 minute sample immersion), part number WG-853 series are for resonators requiring reservoirs ‘off-set’ from the center axis.
***Special Note: Not recommended for contemporary EPR.

Small 50mL Dewar Flasks
When you have plenty of sample signal and experiments take only 15-25 minutes, these small Dewar Flasks are ideal. They can handle up to 4mm OD sample tubes or solid samples mounted onto the end of 4mm OD quartz rods. WG-819s are for resonators requiring reservoirs ‘off-set’ from the center axis.

Technical Tip:
Keeping Dewar Flask reservoirs and “cold-fingers” clean will extend the hold time by reducing the rate of nitrogen boil.

Remember!
Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

Liquid Nitrogen Dewar Flask

Liquid nitrogen is an easily transported and economic source of coolant, whose boiling point is far below the freezing point of water without pressurization. This unique feature makes it useful for a wide range of applications in basic science research such as cell cryopreservation, sample degasification by freeze-pump-thaw cycle and cold trap for experiments involving vacuum lines.

Continuing our goal to remain the world’s leading provider of NMR and EPR consumables and accessories we’ve added a high quality Liquid Nitrogen Dewar Flask for these applications.

Highlights:

~30% cheaper but with equal or better quality than major manufacturers’ corresponding products

~Highly vacuumed (<10-6 torr) and fully silvered cylindrical Dewar minimizes liquid nitrogen loss during storage
~Unique 3 inch aluminum base increases stability
~Better protection for the vacuum hose
~Supplied with Black Ethafoam Stopper

EPR電子順磁共振儀耗材 Dewar Inserts

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)   
EPR Sample Tubes and Accessories    
EPR Cells   
‧ Dewar Inserts  
Dewar Flasks (Cold-Finger Dewars)   
Variable Temperature Accessories    
Electrolytic Cells for EPR    
Miscellaneous EPR Supplies    

Dewar Inserts
•Standard VT Dewar Inserts
•Simple Dewar Inserts
•JEOL Dewar Inserts
•Dewar Insert for Q-Band or Loop Gap Resonators
•Dewar Insert for TM Aqueous Cell
•High Temperature Dewar Inserts

Standard VT Dewar Inserts

These are the most common Dewar Inserts in EPR!
WG-821 and WG-822 Dewar Inserts
Sample tubes 4mm in diameter can be used with any of these Dewar inserts. You can use 5mm tubes in those with “-F” in the product number.

Standard Length Dewar Inserts

Long Dewar Inserts

NOTE: If you need a Dewar Insert with a different diameter or length, with silvering or dimples, please contact us. Wilmad has made many modified Dewar Inserts for spectroscopists like you. Just send us information about your requirements.

Remember!
Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

Simple Dewar Inserts

Need a simple Dewar Insert for your research?

WG-824 and WG-826 Dewar Inserts

Sample tubes 4mm in diameter can be used with any of these Dewar inserts. You can use 5mm tubes in those with “-F” in the product number.

NOTE: If you need a Dewar Insert with a different diameter or length, with silvering or dimples, please contact us. Wilmad has made many modified Dewar Inserts for spectroscopists like you. Just send us information about your requirements.

Remember!
Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

JEOL Dewar Inserts

Why pay more for a replacement JEOL Dewar Insert?

Sample tubes 4 or 5mm in diameter can be used with the JEOL dewar inserts. Sample support dimples can be added, if needed.

Remember!
Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

Dewar Insert for Q-Band or Loop Gap Resonators

Control temperature inside small Q-Band or Loop-Gap resonators.
WG-894 Dewar Insert

You can control the temperature of samples in small resonators by putting the entire resonator in Wilmad’s largest Dewar Insert.

Dewar Insert for TM Aqueous Cell

TM110Aqueous Cell Dewar Insert

To control your sample temperature near ambient in TM Aqueous Cells, use Wilmad’s WG-821-TMR Dewar Insert.

NOTE: Control the temperature of a TM Aqueous Cell near room temperature with this special insert; the upper section is not dewared.

High Temperature Dewar Inserts

At temperatures higher than 300 degrees Celsius, cavity heating is a problem with standard Dewar Inserts. But Wilmad’s WG-821-HT gives you a solution.

Sample tubes up to 4mm in diameter can be used with any ot these high-temperature dewar inserts.

NOTE: Wilmad does not offer a Dewar Insert for the Bruker ER4111HT High Temperature Cavity Resonator system.

EPR電子順磁共振儀耗材 EPR Cells

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)   
EPR Sample Tubes and Accessories    
‧ EPR Cells  
Dewar Inserts   
Dewar Flasks (Cold-Finger Dewars)    
Variable Temperature Accessories   
Electrolytic Cells for EPR      
Miscellaneous EPR Supplies    
EPR Cells
• Standard Aqueous Cells
• Special Aqueous Cells with Hexagonal Fill Tubes
• JEOL Aqueous Cells
• Variable Temperature Aqueous Cells
• Tissue Sample Cells
• Flow Aqueous Cells
• Replacement Parts for Wilmad Tissue and Aqueous Cells

Standard Aqueous Cells

 

Wilmad uses “-Q” to designate quartzware using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

NOTE: Cell product numbers that include the letter “S” indicate that optically polished flat windows are joined to the polished wall ends via a special thermal fusion technique to form an ultra high precision bore flat cell. The two windows are parallel to each other within several visible light wave numbers. These items are recommended for EPR experiments coupled with optical techniques.
***Special Note: Not recommended for contemporary EPR.

Standard TE102Cavity Aqueous Cells

Standard TM110Cavity Aqueous Cells

Special Aqueous Cells with Hexagonal Fill Tubes

These Aqueous Cells are unique due to the shape of the fill tubes. With their hexagonal outer surface, these special cells make alignment easier to reproduce. Can be used with a goniometer.

Wilmad uses “-Q” to designate quartzware using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

NOTE: Cell product numbers that include the letter “S” indicate that optically polished flat windows are joined to the polished wall ends via a special thermal fusion technique to form an ultra high precision bore flat cell. The two windows are parallel to each other within several visible light wave numbers. These items are recommended for EPR experiments coupled with optical techniques.

These Aqueous Cells are unique due to the shape of the fill tubes. With their hexagonal outer surface, these special cells make alignment easier to reproduce. Can be used with a goniometer.

Special TE102Cavity Aqueous Cells With Hexagonal Fill Tubes

Special TM110Cavity Aqueous Cells with Hexagonal Fill Tubes

JEOL Aqueous Cells

The Universal Cavity operates in TE011mode which requires a certain type of aqueous cell for a JEOL spectrometer. Prepared from special thin Suprasil plates, sample thickness is 0.4mm for the WG-LC-11 and 0.3mm for the WG-LC-12.

NOTE: For samples of 50µL or less, please use the capillary sample tubes found Capillary Tubes for JEOL Spectrometers.

Variable Temperature Aqueous Cells

Wilmad uses “-Q” to designate quartzware using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

NOTE: Cell product numbers that include the letter “S” indicate that optically polished flat windows are joined to the polished wall ends via a special thermal fusion technique to form an ultra high precision bore flat cell. The two windows are parallel to each other within several visible light wave numbers. These items are recommended for EPR experiments coupled with optical techniques.

Small Volume TE102Variable Temperature Aqueous Cell
The WG-808 VT Aqueous Cell works with most common VT Dewar Inserts, including WG-821(-X) and WG-848. It has a small volume, so use it only with samples that give a strong signal.

***Special Note: Not recommended for contemporary EPR.

Large Volume TM110Variable Temperature Aqueous Cell
For insensitive samples, larger volumes are needed for sufficient sensitivity. With newer spectrometers, use WG-813-TMS-S(-Q).

Tissue Sample Cells

Aqueous Sample Cells can only be used when your liquid sample can be pulled into the cell using a vacuum. If your samples are viscous, try Wilmad’s tissue cells! Tissue Sample Cells are ideal for studying wet tissues and polymers, e.g. epithelial slices, using EPR.

***Special Note: Not recommended for contemporary EPR.

Flow Aqueous Cells

If you study fast reactions involving free radical intermediates, then you know how difficult it is to capture or “trap” a spectrum of your sample. Flow cells have proven effective in producing a “steady-state” concentration of many reactive intermediates in a microwave cavity resonator.
Room Temperature Aqueous Flow Cell

Variable Temperature Aqueous Flow Cell

NOTE: To use this VT aqueous cell a modified Bruker Transfer Dewar WG-842-MRL may be required
Wilmad uses “-Q” to designate quartzware using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

Replacement Parts for Wilmad Tissue and Aqueous Cells

Quartz Coverplates
All coverplates are 1.6 mm thick and have notches for the support clips used to hold the coverplate in place. They are available in CFQ, Suprasil or TPX plastic**, so you can match the Tissue Cell you already have.
***Special Note: Not recommended for contemporary EPR.

Wilmad uses “-Q” to designate quartzware using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).

TPX Coverplates
TPX coverplates can be used with water-based samples that must be degassed, e.g. for ELDOR or ST experiments. TPX is highly permeable to O2, N2, and CO2. Equilibrate your sample with a stream over the coverslip. Avoid using organic solvents with TPX plastic.
**PLEASE NOTE: TPX Coverplates may have limited availability.

Coverplate Clips
Our special Bronzite clips secure the cover plate to tissue cells without interfering in your spectra.

Replacement Stoppers for Aqueous Cells
If you lose or break a plastic or glass stopper, we can get you replacements quickly. We recommend you stock a few extras. Your experiments should never be halted for lack of a simple quartz or plastic stopper.

EPR 電子順磁共振儀耗材 EPR Sample Tubes and Accessories

EPR電子順磁共振儀耗材
Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)         
• EPR Sample Tubes and Accessories         
EPR Cells     
Dewar Inserts  
Dewar Flasks (Cold-Finger Dewars)   
Variable Temperature Accessories   
Electrolytic Cells for EPR    
Miscellaneous EPR Supplies   

EPR Sample Tubes and Accessories 
• EPR Sample Tubes – Quartz (CFQ)  
• EPR Sample Tubes – Suprasil  
• EPR Graded Seal Sample Tubes  
• Valved and Screw-Cap EPR Tubes  
• Capillary EPR Tubes  
• Special EPR Sample Tubes

EPR Sample Tubes – Quartz (CFQ)
Important Note: Product numbers that include “PQ” belong to our Precision Tube Family with an OD and ID tolerance of ±0.013 mm. Those with “SQ” are not Precision and their OD and ID may vary as much as ±0.4 mm. For EPR experiments that must estimate electron spin density and/or produce highly repeatable signal amplitude between different runs we strongly recommend our Precision EPR Tube.

Save Time Heat-Sealing EPR Samples!
Heat-sealing quartz tubes is difficult enough so we’ve provided an easier way. By ordering our constricted tube you’ll seal EPR tubes more quickly, with less effort. Choose your tube, add the suffix “CONS” to the product number and remember to order 1 inch longer than required.
• Quartz (CFQ) EPR Tubes – 2mm OD
• Quartz (CFQ) EPR Tubes – 3mm OD
• Quartz (CFQ) EPR Tubes – 4mm OD
• Quartz (CFQ) EPR Tubes – 5mm OD
• Quartz (CFQ) EPR Tubes – 10mm OD

Quartz (CFQ) EPR Tubes – 2mm OD

Quartz (CFQ) EPR Tubes – 3mm OD

Quartz (CFQ) EPR Tubes – 4mm OD

Quartz (CFQ) EPR Tubes – 5mm OD

Quartz (CFQ) EPR Tubes – 10mm OD

 ***Special Note: This item not recommended for contemporary EPR****
EPR Sample Tubes – Suprasil
Important Note: Product numbers that include “PQ” belong to our Precision Tube Family with an OD and ID tolerance of ±0.013 mm. Those with “SQ” are not Precision and their OD and ID may vary as much as ±0.4 mm. For EPR experiments that must estimate electron spin density and/or produce highly repeatable signal amplitude between different runs we strongly recommend our Precision EPR Tube.

Save Time Heat-Sealing EPR Samples!
Heat-sealing quartz tubes is difficult enough so we’ve provided an easier way. By ordering our constricted tube you’ll seal EPR tubes more quickly, with less effort. Choose your tube, add the suffix “CONS” to the product number and remember to order 1 inch longer than required.
• Suprasil EPR Tubes – 2mm OD
• Suprasil EPR Tubes – 3mm OD
• Suprasil EPR Tubes – 4mm OD
• Suprasil EPR Tubes – 5mm OD
• Suprasil EPR Tubes – 10mm OD

Suprasil EPR Tubes – 2mm OD

Suprasil EPR Tubes – 3mm OD

Suprasil EPR Tubes – 4mm OD

Suprasil EPR Tubes – 5mm OD

Suprasil EPR Tubes – 10mm OD

EPR Graded Seal Sample Tubes

Need to seal an EPR tube to your vacuum rack?
Some EPR samples are air-sensitive. Since oxygen is paramagnetic, many EPR samples are best studied after degassing. For long-term storage, no other closure is better, but most vacuum racks incorporate Pyrex components. Sealing quartz to Pyrex is a problem, unless you use sample tubes that incorporate a graded seal. Order Wilmad’s Graded Seal/Constricted EPR Tubes, available in a variety of sizes. Other configurations can be prepared, so if you don’t see the size you need, contact us about price and availabiility

Valved and Screw-Cap EPR Tubes
• J. Young EPR Sample Tubes, Valves and Pistons
• Screw Cap EPR Sample Tubes

J. Young EPR Sample Tubes, Valves and Pistons

Wilmad’s J. Young valved sample tubes make difficult samples easy to study. No wonder they’ve become so popular in NMR. Now, you get the same advantages in EPR studies!

It’s a real bargain, too! One tube handles:

 • air-sensitive samples
 • degassed samples
 • catalytic studies
 • gaseous samples
 • volatile samples

The J. Young Valve EPR Tube saves time. No greasy joints to fuss with. Connect it quickly to your vacuum rack. Opens and closes with a quick twist of the wrist. We can add the valve atop any Wilmad EPR sample tube 5mm OD or larger. A graded seal is used to connect the Pyrex portion of the valve to a quartz EPR tube. Two sizes of the valve are available. One is ideal for 5mm tubes, the other for 10mm tubes. One is right for most every EPR sample tube you get from Wilmad.

Replacement pistons and vacuum adapters are sold separately. If you should break the tube, but not the thread, it can be repaired at a cost that’s lower than a new one.

J. Young Valves and Pistons

Screw Cap EPR Sample Tubes

Now, sample tube and storage vial have been joined!
Save time and money with the Screw Cap EPR Tube; each come with a PTFE/Silicone Septum.

Quartz (CFQ) Screw Cap EPR Tubes

Suprasil Screw Cap EPR Tubes

Replacement Septa and Caps

*PTFE/Rubber – Laminated discs consisting of a sheath of Teflon®bonded chemically to white pharmaceutical rubber. Inert to most solvents and many corrosives. Not recommended for multiple punctures.

PTFE/Silicone – Laminated discs consisting of a Teflon®sheath bonded chemically to silicone rubber. Inert to most organic solvents and compounds; however, not recommmended for use with strongly corrosive materials. Resealability properties of silicone rubber are excellent.

Capillary EPR Tubes
• Capillary Tubes for JEOL Spectrometers
• Quartz and Suprasil Capillary Tubes

Capillary Tubes for JEOL Spectrometers

Recommended for use when small aqueous samples are studied using JEOL’s standard TE011cylindrical cavity resonator, these sample “cells” are more durable and easier to handle because of their heavy wall construction (OD = 4.0mm). Made from the highest quality synthetic Suprasil quartz, these capillary cells provide excellent performance at temperatures from 5 to 100°C. You’ll find these cells are fully compatible with JEOL’s tube caps and collet for 4mm OD tubes.

These JEOL capillary sample tubes are used with collet adapters. Collets not included. They are available here:

NOTE: Wilmad does not offer tubes for dosimetry. Please contact the manufacturer of your dosimeter for information about these special sample tubes.

Quartz and Suprasil Capillary Tubes

Conveniently packaged in vials of 25, 50, and 75 pieces, Wilmad Clear Fused Quartz and Suprasil capillary tubes are often used in EPR applications where sample sizes are limited. Available in sizes from 0.40 to 2.4mm OD, these fine tubes are 100mm long and open on both ends. Easy to seal with a hot flame, you can use them with a round bottom or close with a sealant of your choice (beeswax is commonly used.)
Clear Fused Quartz Capillary Tubes

Suprasil Capillary Tubes

NOTE: Wilmad does not offer tubes for dosimetry. Please contact the manufacturer of your dosimeter for information about these special sample tubes.

Special EPR Sample Tubes

High Temperature Sample Tube for Bruker ER4114HT Dewar Insert

Only by making a tapered joint seal with the Dewar Insert is it possible to achieve the highest temperatures with Dewar Insert for Bruker’s ER4114HT Cavity Resonator. Wilmad makes a unique sample tube for use with this special dewar insert. Consisting of a 6mm OD tube that tapers to a 4mm OD below a7/15 inner joint, this tube is prepared with CFQ.

Impurity Analyses-Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)

EPR電子順磁共振儀耗材 
• Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)   
EPR Sample Tubes and Accessories   
EPR Cells    
Dewar Inserts     
Dewar Flasks (Cold-Finger Dewars)        
Variable Temperature Accessories       
Electrolytic Cells for EPR     
Miscellaneous EPR Supplies    

Impurity Analyses – Clear Fused Quartz (CFQ) vs. Suprasil (Synthetic Quartz)
Clear Fused Quartz (CFQ) is purified from naturally occurring quartz so the existence of certain material radicals from mining is inevitable. Chemical impurity analysis results for CFQ are shown below:
Table 1: Impurity Analysis for Clear Fused Quartz (unit: ppm in weight)

Due to technological advancements the sensitivity of EPR has gradually increased. The direct result is that certain high Q cavities will pick up the signal from these impurities, especially in tubes of over 4 mm OD. In this case we recommend switching to Suprasil® EPR products which are made of synthetic material and suppress major impurity contents shown in Table 1 by the average of 2 orders of magnitude. Impurity analysis test results for Suprasil® are shown below:

Table 2: Impurity Analysis for Suprasil Quartz (unit: ppm in weight) 

Important Note: Product numbers that include “PQ” belong to our Precision Tube Family with an OD and ID tolerance of ±0.013 mm. Those with “SQ” are not Precision and their OD and ID may vary as much as ±0.4 mm. For EPR experiments that must estimate electron spin density and/or produce highly repeatable signal amplitude between different runs we strongly recommend our Precision EPR Tube.

Consumables and Accessories for Solid-State NMR

NMR核磁共振儀耗材
1. NMR Sample Tube選用對照表  
2. Standard Consumables for Liquid-Phase NMR  
3. Consumables for Liquid-Phase small Volume and ExternalReference NMR Studies     
4. Gas-Tight Consumables for Liquid-Phase and Gas-Phase NMR 
5. NMR Reference Solutions  
6. Accessories for Liquid-Phase NMR
7. Consumables and Accessories for Solid-State NMR

Consumables and Accessories for Solid-State NMR

Rotors and Caps for Bruker®, Varian® and Doty® MAS-NMR
Zirconia MAS Rotors and Caps
Manufactured from the highest purity Zirconia, Wilmad’s MAS Rotors provide the NMR
spectroscopist with the ultimate alternative for analysis of solid samples. The need to solvate solid samples is eliminated. They are available for most current solid state NMR spectrometers.
Wilmad MAS Rotors are carefully examined for material irregularities by optical methods before and after the precision machining process. Without overspinning, each rotor is spin tested to only the highest specified spinning speed. High precision (which becomes a necessity for proper spinning performance) is maintained in the manufacture of the end caps. Most end caps are fitted with O-rings for better sealing. Some caps have axial holes for venting.

Advantages of Zirconia Rotors
• Most homogeneous ceramic material
• Wilmad’s Zirconia Rotor Body has higher strength (1,000 MPa, greater than Si3N4)
• Highest spinning speed (up to 12 kHz for 7 mm O.D. rotors)
• High precision superior finish (0.05 μm mirror gloss)

                                     Properties of Rotor and Cap Materials

                               Rotor and Cap for Doty® MAS Probe

                                     Rotor and Cap for Bruker® MAS Probe

                              Rotor and Cap for Bruker® MAS Probe (continued)

For Operating Caps: No special tools are needed to put in or take out of rotor. They should NOT be pressed in as this may damage the O-ring. Ensuring the cap shaft and the rotor are aligned, cap should be screwed in; when the cap is in completely it should be turned back slightly (approximately 1/4 turn). Remove in the same fashion.

                            Rotor and Cap for Varian® Jakobsen MAS Probe

 

Pyrex MAS Rotor Inserts
Our Pyrex® MAS Rotor Inserts are designed for air-sensitive samples and semi-solid samples such as gels or highly viscous liquids. Sample can be sealed into the insert tube by heat-sealing with a torch or applying a small drop of epoxy (we recommend E-6000® Jewelry and Craft Adhesive) to the constricted part as shown below. After the epoxy is set and dry (24 hours) the sealed insert is cut through the constriction with a glass saw.
Using a small funnel (p/n 815), powder samples can be packed into the insert. Gelatinous samples can be warmed and transferred to the insert using a syringe.
Note: A glove box may be needed for the sealing of air-sensitive samples.

 


Pyrex Tubes for Varian NanoProbes
Wilmad’s Tubes for Varian® NanoProbe are constructed of Pyrex® glass for NMR analysis of
solids and semi-solids. This product is specially machined at close tolerances which allows the
tube to operate at around 2.5 kHz rotating speed.
Features:
• Each cap has an axial hole for venting air from the tube.
• A small screw plug is optional for closing the hole in experiments to prevent evaporation and
/or spill.
• Air-tight O-ring seals are optional on caps and plugs.
• Three Volumes are available:
110 μl – each consisting of a Pyrex® tube and a cap (Ertalyte or Kel-F®)
60 μl and 40 μl – each consisting of a Pyrex® tube, a cap and a plug (Ertalyte or Kel-F®)
Overall Size – 4 mm O.D. x 22.5 mm Length

                                        Properties of Cap and Plug Materials

                                            Non-GHX type Varian® NanoProbe

                                              GHX type Varian® NanoProbe


Stainless Steel Micro-Spatula
Getting a tiny powder sample into any tube larger than 4 mm O.D. tube should never be a struggle again. Unlike ordinary spatulas, Wilmad’s Stainless Steel NMR Spatula fits into the most common NMR tubes. Add or remove samples easily, (including freeze-dried); scoop samples with the round end or pry stiff samples with the sharp edged flat end.

核磁共振儀耗材 Accessories for Liquid-Phase NMR

NMR核磁共振儀耗材
1. NMR Sample Tube選用對照表  
2. Standard Consumables for Liquid-Phase NMR   
3. Consumables for Liquid-Phase small Volume and ExternalReference NMR Studies
4. Gas-Tight Consumables for Liquid-Phase and Gas-Phase NMR
5. NMR Reference Solutions
6. Accessories for Liquid-Phase NMR
7. Consumables and Accessories for Solid-State NMR

Accessories for Liquid-Phase NMR

Spinner Turbines
Wilmad supplies a full range of Spinner Turbines for Varian/Nalorac and Bruker NMR spectrometers from 1.7mm to 10mm. These Spinner Turbines are manufactured to precision standards that exceeds spectrometers manufacturers’s products in terms of dimension tolerance, reliability and life span.

 Spinner Turbines for Bruker®  Spectrometers

STB-5 ROOM TEMPERATURE 5 MM SPINNER TURBINE
Highlights: 
– Causes less probe insert damage by better insert sample control.
– Tachometer strip now with foil protection for improved life span.
– Longer upper barrel stabilizer easily identified by 3mm yellow band.
– Limited VT operation possible of +40°C above ambient.
– Can be mixed with originals during sample changer operation.
– Susceptibility matched to the originals.


B-PEEK-5 VARIABLE TEMPERATURE 5 MM AMD 10 MM SPINNER TURBINE

Highlights: 
– Causes less probe insert damage by better insert sample control.
– Tachometer strip now with foil protection for improved life span.
– Longer upper barrel stabilizer easily identified by 3mm yellow band.
– Variable temperature operation from -150°C to +200°C.
– Can be mixed with originals during sample changer operation.
– Weight compatible with room temperature spinners.
– Susceptibility matched to the originals.
– Far less likely to break as compared with ceramic spinners if dropped on a hard surface, and more economical.
– Long life high temperature o-rings at top and bottom.


3 TO 5 MM SPINNER TURBINE VARIABLE TEMPERATURE WITH EXCHANGEABLE FINGERS
Highlights: (in addition to STB-5 and B-PEEK-5) 
– Cost effective compared to the full VT version for sample changers
– Allows a portion of the VT air to pass straight past the sample inside the spinner turbine therefore reducing VT gradients and micro sonic flutter due to a high VT flow
– Includes high temperature external O-rings at the top and bottom for long life and a firm grip on the sample at top and bottom.
– Can also be used for spinning experiments.

 
Spinner Turbines for Varian®  Spectrometers

STV-5 ROOM TEMPERATURE 5 MM SPINNER TURBINE
Highlights: 
– Low cost alternative to the full VT version for sample changers.
– Weight and susceptibility matched to originals.
– Can be mixed with originals in sample changer operation.
– Limited VT operation around ambient.
– Does not jam at top of upper barrel during insert operation.
– Tachometer strip now with foil protection for improved life span.


V-PEEK-5 VARIABLE TEMPERATURE  5 MM AND 10 MM SPINNER TURBINE
 Highlights: 
– Low cost alternative to the full VT version for sample changers.
– Weight and susceptibility matched to originals.
– Can be mixed with originals in sample changer operation.
– VT operation of -150°C to 200°C
– Does not jam at top of upper barrel during insert operation.
– Tachometer strip now with foil protection for improved life span.
– Weight compatible with room temperature spinners.
– Very cost effective as compared to the originals.


3 to 5 MM SPINNER TURBINE VARIABLE TEMPERATURE WITH EXCHANGEABLE FINGERS
Highlights: (in addition to STV-5 and V-PEEK-5) 
– Cost effective compared to the full VT version for sample changers
– Allows a portion of the VT air to pass straight past the sample inside the spinner turbine therefore reducing VT gradients and micro sonic flutter due to a high VT flow
– Includes high temperature external O-rings at the top and bottom for long life and a firm grip on the sample at top and bottom.
– Can also be used for spinning experiments.


 

Spinner for Small Volume NMR (Bruker® MATCH® System)
Similar to Bruker® MATCH® system, Wilmad’s Spinner for Small Volume NMR holds a variety of microsample capillaries and is compatible with Bruker®, Varian®, JEOL®’s spectrometers/probes and automatic sample changers. A substantial savings is realized considering the“one size” variety available from NMR probe manufacturers.
The lower portion of each insert fits precisely into the Spinner Turbine; the upper portion holds a short 10 mm NMR tube (almost 4 inches long with open ends) that extends beyond the top. This set-up can be used with autosample changers that grasp the tube above the turbine.


 

Tube Washers

Universal solvent Jet NMR Tube Washer
Wilmad’s Universal Solvent Jet Washer can be used for any length sample tube by a simple adjustment of the flexible PTFE tubing. It is espcially recommended for cleaning our gas-tight sample tubes.
By loosening and retightening the tubing fitting on the assembled washer head, the PTFE tubing that extends into the sample tube is adjusted to the proper length. The washer head is then affixed to a filter flask (with sidearm) and the side tubing is inserted into a washing solvent reservoir. After an inverted sample tube is placed over the PTFE tubing, a vacuum is applied to the flask and the sample tube is pressed against the rubber gasket to form an air-tight seal that starts the solvent flow. By lifting the PTFE tubing out of the solvent reservoir, the sample tube can be air-dried.


Multi-Tube Jet Solvent NMR /EPR Tube Washer/Dryer
Wilmad’s new generation Multi-Tube Jet Solvent Washer/Dryer is recommended for research labs that routinely clean NMR/EPR tubes; a single unit can accommodate up to 5 tubes (5 mm OD) at once. When an inverted tube is inserted onto the PTFE tubing and the open end is immersed under wash solvent in the solvent cup, a reliable vacuum-tight seal will be formed and generate solvent flow under vacuum. After solvent is fully consumed, air flow will follow to
turn the unit into a dryer.

Features:
• Novel design significantly increases the reliability and performance compared to traditional jet solvent washer/cleaner systems.
• PTFE solvent cup and tubing make this unit fully resistant to common organic solvents.
• Greaseless joint between the solvent cup and glass reservoir eliminates possibility of contamination.
• Open design allows for easy cleaning after each use.
• Hands Free during washing/drying cycle.
• Detachable side-arm with screw thread provides convenient vacuum hose connection.



After fitting the washer to a filter flask, an inverted sample tube is inserted into the washer and solvent is introduced into the reservoir using a series of wash bottles. You can perform numerous wash steps and finish by pulling air through the tube to complete the procedure.
Filter flasks are ordered separately. The single tube washers (WG-1207-series)require flasks with vacuum sidearms (see below).

Economy Single Tube Solvent Jet Washer/Cleaner


Filter Flasks with Vacuum Sidearms
Filter flasks have a standard taper Ts 24/40 outer joint and are used with WG-1207 Economy Single Tube Washer and WG-7200 Universal Tube Washer.


Ultrasonic Cleaning Systems
The Ultrasonic Cleaning Systems can wash up to 20 tubes at a time and are recommended for NMR research facilities. Operating at 21,000 sonic vibrations per second, these versatile, compact units can be used with aqueous detergent solutions or organic solvents (tank manufactured from stainless steel).
These Ultrasonic Cleaners have a 1 gallon capacity. Tube Cleaning Rack is plastic-coated to protect tubes. Available in a number of configurations, e.g. with 0-30 min timer and/or heater (thermostated for 60 °C) these units provide up to 100 watts output while drawing a maximum of just 1 A input power.

Capacity: 1 gallon (approximately 3.8 liters)
Tank D imensions: 9” x 5” x 6” deep
Outer D imensions: 10 1/2” x 6 1/2” x 11” high

 
NMR/EPR Tube Racks

 
Spinner Bearing NMR Tube Tester


 

Liquid Nitrogen Dewar Flask

Liquid nitrogen is an easily transported and economic source of coolant, whose boiling point is far below the freezing point of water without pressurization. This unique feature makes liquid nitrogen extremely useful for a wide range of applications in basic science research, such as cell cryopreservation, sample degasification by freeze-pump-thaw cycle and cold trap for experiments involving vacuum lines.
Wilmad, the world’s leading provider in NMR/EPR consumables and accessories, now has a high quality Liquid Nitrogen Dewar Flask to meet these applications.
Features:
• 30% cheaper than other manufacturers’ similar products.
• Unique metal base increases stability.
• Optional full length aluminum metal housing can further increase safety and reduce potential breakage.
• High vacuum minimizes liquid nitrogen loss during storage.


Combination pH Electrode
For use in 5 mm thin-walled NMR sample tubes up to 8” in length. Glass probe dimensions are 3 mm O.D. x 180 mm length.


 NMR Long Tip Transfer Pipets and Accessories

NMR Filters and Powder Funnel
Sample sedimentation may bring trouble to both shimming and spectrum quality. Use Wilmad’s special Bulb Filter to remove large particles. Two designs available: one with luer tip for stainless steel needle attachment, the other with glass tip. Both fit into all sizes of Wilmad NMR tubes. The sintered glass tip removes particles larger than 60 μm.

Wilmad’s Powder Funnel is designed to load large amounts of liquid reagents into NMR tubes. Tip fits into 5 mm thin-walled NMR or larger tubes.


 

Hamilton® Gas Tight Syringes (PTFE Luer Lock)
Wilmad offers PTFE Luer Lock syringes that best meet your NMR sampling needs.
These syringes handle air-sensitive and/or volatile samples with precise control over sample volumes.
Features:
• Gas and Liquid Tight.
• Reproducible (volumes to ± 1%).
• Made of inert borosilicate glass, PTFE, and stainless steel.
• Pressure tight to 200 psi.


 

Syringe Needles
The stainless steel needle is designed for septum punctures for air-sensitive sample.
The PTFE version in various sizes offer a convenient way to load and wash your sample in Small Volume NMR experiments.

 
Turbine Height Adjuster for Auto Sample-Changer
Wilmad offers a solution to save your valuable time in NMR Auto Sample-Changer turbine height adjustment.
Each adjuster has a set screw that lets you adjust the position of the turbine along the tube to match your instrument. Two versions are available for Bruker®, Varian® and JEOL® systems.

 
Vortex Plugs and Positioning Rods
Recommended for sample positioning inside the NMR tube.

 
Pressure Sensitive NMR/EPR Tube Labels
Wilmad’s Pressure Sensitive NMR Tube Labels are a handy alternative to marking tubes. Each label fits the circumference of the NMR tube precisely with no overlapping to guarantee sample tube’s symmetry in spinning experiment.